Filter:
High Efficiency Particulate Air (HEPA) type with a minimum efficiency of 99.99% at 0.3 micron.
Pre filler:
Woven polyester with frame.
40% ASHRAE test method
52.76. Extends the life of the
HEPA filter.
Construction:
All aluminum filter plenum and blower housing with exterior finish in polyurethane enamel.
Power cord:
Standard 5-15 115V, single phase, 60 Hz. rubber covered cord with 3-prong, hospital grade grounded plug.
|
|
Motor/Blower assembly:
Direct drive, continuous duty 1/3 h.p. with sealed-for-life bearings and inherent overload protection. Located on the "clean side" of the filter. Motor/blower assembly is electronically balanced and mounted on vibration dampening rubber mounts.
|
Avg
CFM
|
UL
Listing
|
Power Requirements |
Approx Ship |
400 Low 600 Med 800
High |
All Parts |
AMPS AT 115V: 3.9 |
125 lbs (56.82Kg) |
|
4" Exhaust port:
Able to exhaust air out of the unit from the top.
Low dBA:
52 at low, 56 at medium, and
60 at high speed.
|
Casters:
Four 3" casters, 2 locking.
Dimensions:
61" H x 24" W x 15.5" D
I 54.94cmx60.96cmx39.37cm
|
|